10× the usable data.
1/10th the cost.
One 40‑minute run.

From 1 sequencing-ready tumor sample in 16 to 10, at a hard 70% viability cutoff.

52%75%median viability after one 40-minute, label-free run
9in 10dead cells removed from a typical sample; debris cut in half
1/10the costper sequencing-ready dataset at a hard 70% cutoff; 38% lower if half of below-gate samples are salvaged

Levitated samples, sequencing-ready data. Discovery Life Sciences ran 16 cryopreserved tumor samples through one label-free, 40-minute levitation step, then sequenced ten of them twice with the Parse Evercode WT assay: untouched and levitated. More live cells, less debris, cleaner libraries, lower cost per dataset.

LeviCell with the LeviSelect Cell Debris Depletion Kit. 16 samples counted at the bench, 20 paired Parse Evercode WT libraries, 21 quality metrics. September 2026.
Download the one-page study summary (PDF)

Study conducted byEvercode WT assay by
Live cells levitate into one band, ready to collect
Dead cells and debris sink out of the way

0 minSample loaded. Thawed suspension, mixed.

Live cellsDead cellsDebris

The problem starts at thaw.

Cryopreserved tumor samples arrive with half their cells dead, and every single-cell platform wants viability of 70% or better.

48%

of cells were dead at thaw, the median across all 16 samples.

15of 16

samples were below a 70% viability threshold when thawed.

68%

of transcripts were ambient RNA in the most contaminated sample. Reads spent on soup, not cells.

Dead cells and debris consume barcodes, sequencing reads and analyst time. A sample that fails QC wastes irreplaceable patient tissue and puts the study on hold while a replacement is sourced.

One label-free step. Forty minutes.

Levitation separates live cells from dead cells and debris using their native physical properties. No antibodies, beads, columns or centrifugation shear. Nothing touches the cells.

Load

Thawed or fresh suspension goes straight into the levitation plate, with as few as 15,000 cells.

Levitate

Live cells, dead cells and debris settle at distinct heights in the magnetic field.

Collect

Recover the live-cell fraction and proceed to 10x, Parse or flow. Forty minutes, walkaway.

Replaces three steps

Compatible with fresh, thawed and fixed-cell workflows.

Dead-cell removal kits
Beads and columns. Dead cells only; debris stays.
Cell strainers
Aggregates only. Dead cells pass straight through.
FACS live sort
Core scheduling, operator time, nozzle shear on fragile cells.

LeviCell alone

Label-free live-cell enrichment that keeps every population: immune, epithelial and stromal cells all represented. The right protocol for tumor microenvironment, fibroblast and vascular questions.

Validated by Discovery Life Sciences on more than 100 cryopreserved samples across 20 indications: 80% dead-cell and debris removal, 100% of samples improved.

Protocol used in this study

LeviCell with the LeviSelect Cell Debris Depletion Kit

Deeper debris depletion for heavily contaminated cryopreserved samples. The kit also depletes stromal cells, fibroblasts and endothelium, removed whole rather than lysed, so nothing leaks into the background. Lymphocytes come through essentially intact.

Chosen here to maximise clean-up and focus the analysis on the immune compartment. Live-cell enrichment and dead-cell removal are core LeviCell performance; the kit adds read depth and population focus.

The study

Run by Discovery Life Sciences on Discovery biobank material. Analysis by LevitasBio.

Study conducted byEvercode WT assay by

All 16 cryopreserved dissociated tumor samples came from the Discovery biobank and were counted at the bench before and after levitation. Ten also went on to sequencing, each prepared twice, as-is and levitated: 20 libraries built with the Parse Evercode whole-transcriptome (WT) assay, Parse's combinatorial barcoding chemistry, and processed with split-pipe 1.9.0, compared pair by pair at matched depth, with one rule set applied identically to every library. The 21 quality metrics are how many ways data quality was measured: viability, debris, ambient RNA, doublets, cell-type composition, marker genes, cell cycle and more.

What one run did to the samples.

Bench counts on all 16 samples, then 10 of them through the Parse Evercode WT assay, 20 libraries in all, sequenced and processed with Parse's split-pipe pipeline. Grey is the sample as it thawed. Teal is the same sample after levitation.

52%75%

Half the cells alive at thaw. Three quarters after.

Across the 16 samples, the typical sample went from 52% live cells at thaw to 75% after one run, a gain of about 24 points. Every one of the 10 samples that went on to sequencing improved. The dirtier the sample, the bigger the gain: the largest took a colorectal sample from 40% to 86%.

Viability by acridine orange / propidium iodide, counted before and after the LeviCell run. 52% and 75% are medians of all 16 samples; the 10 sequenced samples averaged 52% to 78% (p = 0.002). Two samples did not improve: Lung 1 (53% to 52%) and Bladder 2, a 38,000-cell sample with 97% debris at thaw (80% to 50%).

Viability at thaw (grey) and after levitation (teal). The dashed line is the 70% gate most droplet and combinatorial single-cell workflows recommend.

110of 16

Rejected samples become datasets.

At thaw, one sample in sixteen cleared a 70% viability gate. After levitation, ten did. Seven samples began under 50% viability; all seven improved, and five of them reached 77% or higher, from unusable to sequencing-ready.

Viability thresholds vary by platform and protocol; 70% is a common minimum recommendation. Pick a gate to see how many samples clear it.

At thaw

1 of 16 samples ready

After levitation

10 of 16 samples ready

What didn't improve

Two of the 16 samples did not gain viability. Lung 1 was flat (53% to 52%). Bladder 2 was a 38,000-cell input with 97% debris at thaw (80% to 50%), below what the bench counts could measure reliably, and it is excluded from the dead-cell panel for that reason. Both are in every chart on this page. A confirmatory same-run study is in progress, and a kit-free arm is planned for it.

9in 10

Nine in ten dead cells gone. Debris cut in half.

Two different things leave the tube. Dead cells: a typical sample lost 89% of them (range 76% to 99%). Debris: its share of everything in the tube fell from 30.7% to 14.9%, and in the dirtiest samples 88% of the debris pieces were removed.

Why "half" and "88%" are both right: debris is counted as a share of everything left in the tube, and the run also removes most of the dead cells, so the total shrinks too. Half the share works out to roughly three quarters of the debris pieces gone from a typical sample, and 88% from the dirtiest.

Dead cells counted by AO/PI before and after; debris is anything in the brightfield image that is not a cell. Bladder 2 (38,000 cells, 97% debris) had counts too small to measure removal reliably and is excluded here.

Top two bars: the share removed. Dirtiest samples means more than 40% debris at thaw. Bottom row: how much of everything in the tube is debris, before (grey) and after (teal).

21%less

Less ambient RNA, where it matters most.

The share of transcripts sitting in background barcodes rather than in cells fell from 6.45% to 5.09% at the standard cutoff, and was 16% to 21% lower at every cutoff tested, in 9 of 10 sample pairs (p = 0.004). The dirtier the input, the bigger the clean-up: the most contaminated sample lost more than half its ambient RNA, 68% to 32%.

Ambient RNA is free-floating RNA from dead and damaged cells that leaks into every cell's barcode and blurs the data. Bench debris counts fell in the same direction, and the background that remains is the same soup, just less of it.

10 sequenced samples, each as-is and levitated (20 Parse Evercode WT libraries), pairs downsampled to equal depth. The result holds at every background cutoff, so it does not depend on where the line is drawn.

6×fewer

Aggregates out: six times fewer doublets.

High-confidence doublets fell from 0.42% to 0.07% of cells, adjusted for cell-type mix (p = 0.020), and from 0.19% to 0.03% at the strictest threshold (p = 0.008). All nine detected cell populations had fewer doublets after levitation, despite denser loading of Parse's barcoding wells in the levitated arm (967 to 1,224 cells per round-1 well), which should have produced more collisions, not fewer.

A doublet is two cells stuck together and read as a single cell: a fake data point that has to be found and thrown out. Levitation removes clumps physically, so fewer doublets ever reach the sequencer.

Scrublet on 79,318 depth-matched cells, one common threshold for all 20 libraries. Levitated suspensions also spread more evenly across barcoding wells, consistent with a better-dispersed suspension.

85of 100

Your biology comes through unchanged.

Of each population's top-100 marker genes, 85 on average remain significant after levitation, with 90% to 97% carrying over in most populations. Expression profiles from the two arms agree as closely as two random halves of the same library (0.852 against a ceiling of 0.854). Proliferating cells were retained: 35% to 40% in S or G2/M, up in 8 of 10 pairs.

Every cell type is recognised by a set of marker genes. The same genes identify each cell type in the levitated data as in the untouched data, so a lab would reach the same conclusions from either dataset. Levitation changes the input, not the answer.

Top-100 marker overlap averages 64 genes against 0.3 expected by chance. Tumour-cell cluster purity unchanged (93.4% to 92.9%, not significant).

12.5%24%

With the kit: immune cells kept, stroma depleted.

Lymphocytes come through intact. B and plasma cells are retained at about 100%, T and NK cells at 75%, and their share of each library roughly doubles: T/NK from 12.5% to 24.0% (p = 0.008), B/plasma from 7.4% to 12.6% (p = 0.004). The kit removes fibroblasts and endothelial cells in every pair, whole rather than lysed.

Stromal depletion is a property of the Debris Depletion Kit protocol, not of levitation itself. Need the microenvironment? Run LeviCell without the kit and keep every population.

Share of each library's cells in each population before (grey) and after (teal) the kit run. Both arms of each sample clustered together; shares compared within each pair.

Want to see these results on your own samples?

Contact us

Where levitation earns it back.

What one cryopreserved tumor sample costs to turn into data, and what changes when a typical sample gains 24 points of viability before the library is built. At a hard 70% cutoff, where a below-gate sample is a write-off, the same 16 samples yield 1 sequencing-ready dataset without levitation and 10 with it, so the cost per dataset falls to about one tenth. The model below also shows the gentler case where half of below-gate samples are salvaged.

$0.65$0.45

31% less per usable cell.

Library prep, sequencing and analysis cost the same whether a cell was alive or not. Load 10,000 cells at 52% viability and $3,400 of downstream spend is spread over 5,200 live cells. At 75% viability it is spread over 7,500. In heavily contaminated samples, that is up to 2.2 times more usable reads per sequencing dollar.

Downstream spend per live cell, 10,000 cells loaded, input not limiting.

Of 10,000 cells loaded, how many are alive and worth a barcode.

110datasets

Same 16 samples. One dataset without levitation, ten with.

Run the 16 samples either way and you pay for 16 thaws, 16 library preps and 16 sequencing runs. At a hard 70% cutoff, only 1 of the 16 becomes a sequencing-ready dataset without levitation; with it, 10 do. The spend is almost the same, so each dataset costs about a tenth as much.

Pass rates from this study: 1 of 16 clear a 70% gate at thaw, 10 of 16 after. Clean-up costed at $350 for a dead-cell kit or sort versus $10 for LeviCell consumables. If your lab salvages half of its below-gate samples instead of writing them off, the saving per dataset is 38%.

Without LeviCell

16 samples run, 1 dataset.

With LeviCell

16 samples run, 10 datasets.

The same 16 samples, hard 70% cutoffWithoutWith LeviCell
Samples bought, thawed, prepped and sequenced1616
Sequencing-ready datasets110
Samples paid for that yield no dataset156
Total study cost$96,800$91,360
Cost per sequencing-ready dataset$96,800$9,136

Teal tiles are samples that became datasets; crossed tiles were paid for and yielded none. Ten times the datasets from the same tissue, for about the same spend.

$1,940per sample

Net saving on every sample you run.

Each cryopreserved tumor sample costs about $5,700 to turn into data. Levitation earns back roughly $1,940 of it, and up to $2,350 on heavily contaminated samples, for a $10 consumable.

Where levitation pays back, per sample

  • Failed-run spend avoided+$1,600

    Expected loss on a below-gate sample falls from $2,670 to $1,070.

  • Dead-cell kit or live sort replaced+$350

    Reagents and core time for the step levitation makes unnecessary.

  • Sequencing efficiency on contaminated samples+$400

    2.2 times more usable reads per sequencing dollar when ambient RNA is high.

  • LeviCell consumables−$10

    Per-sample consumable cost.

Net saving per sample≈ $1,940

Run the model with your own numbers.

Your samples, your costs, this study's pass rates at the gate you choose. Both arms run the same samples; the question is how many become usable datasets, and what each one costs.

Viability gate

Cost per sample, US dollars

10 datasetsfrom the same 16 samples, instead of 1 without levitation

The same 16 samplesWithoutWith LeviCell
Usable datasets110
Samples paid for that yield no dataset156
Total spend$0$0
Cost per usable dataset$0$0
Downstream cost per usable cell$0$0

Send this model to our team

Your inputs and results go to sales@levitasbio.com, and we reply with the full breakdown.

Pass rates at each gate are this study's (16 cryopreserved tumor samples), applied to the samples you enter and rounded to whole datasets. Viability after levitation is taken as your thaw viability plus the study's median per-sample gain of 24 points, capped at 90%. Illustrative; replace any input with your own quotes.

Model assumptions and sensitivity
  • Procurement $2,000 per vial: commercial dissociated tumor cell list prices run about $1,700 to $2,000 per 1M-cell vial.
  • Library prep $2,250: 10x 3' GEX core rates run about $1,750 to $3,400 per sample; multiplexed kits lower.
  • Sequencing $750 for about 150 M reads: core rates run about $540 to $715 per 300 M single-cell reads.
  • Thaw, QC and labor $300; analysis $400; dead-cell kit or sort $350; LeviCell consumables $10 per sample.
  • Failure model: both arms process the same 16 samples; a sample below the viability gate yields unusable data 50% of the time. Pass rates from this dataset: 1 of 16 at thaw and 10 of 16 after levitation clear a 70% gate. Seen the other way round, a lab that needs 16 usable datasets would have to run 31 samples without LeviCell and 20 with it. The sequencing-efficiency lever is applied only to heavily contaminated samples.
  • Protocol: all results with LeviCell plus the Cell Debris Depletion Kit, which also depletes stromal cells. Kit-free runs preserve population representation; a kit-free arm is planned for the confirmatory study. Both sequencing arms were processed with the same software (split-pipe 1.9.0), and every result reproduced exactly on reprocessing.

Reduction in cost per usable dataset. Rows are the viability gate; columns are the share of below-gate samples that produce unusable data. The highlighted cell is the base case used on this page.

Gate25% fail50% fail75% fail
50%−16%−26%−37%
60%−23%−41%−62%
70%−20%−38%−61%

Questions about the numbers, or pricing for your lab?

Contact us

What the spreadsheet doesn't capture.

Downstream software can model contamination. It cannot recover a sample that was never viable.

Irreplaceable tissue

A consented patient sample that fails QC cannot be re-ordered. Levitation puts it in the study instead of the freezer, or the bin.

Calendar time

Sourcing a replacement sample takes weeks to months. In this study, four to five more of the same 16 samples become usable datasets, each one a replacement you never have to source.

Hands-on time

A 40-minute walkaway run in place of an hour or more of bead kits, spins and sorter time, and no core-facility queue.

32%84%

Customer report, 10x Genomics workflow. Cryopreserved dissociated tumor tissue at 32% viability after thaw came off the LeviCell at 84%: a precious patient sample processed for single-cell capture instead of discarded.

Make levitation the first step in every tumor workflow.

What we measured, all 16 samples

  • 52% to 75% median viability; every sequenced sample improved
  • 89% of dead cells removed; optical debris halved
  • 10 of 16 samples cleared a 70% gate, up from 1
  • 47% to 81.5% colorectal median

What Evercode WT sequencing showed, 20 libraries

  • 21% less ambient RNA, 9 of 10 pairs
  • 6× fewer high-confidence doublets, every population lower
  • 85 of 100 marker genes carry over
  • Immune cells retained intact with the kit; dividing cells kept

What it means for budgets

  • 1/10th the cost per sequencing-ready dataset at a hard 70% cutoff; 38% lower with half of below-gate samples salvaged
  • 2.3× more usable cells per dollar
  • ≈ $1,940 net saved per sample
  • $350 kit or sort step replaced by a $10 consumable
Download the study summary (PDF) Contact us

To contact us and learn more, email sales@levitasbio.com or visit levitasbio.com.

Study conducted byEvercode WT assay by
Contact us

Talk to our team

Leave your details and the LevitasBio team will get back to you.

Your details go to sales@levitasbio.com.